INDEX
40
T-SERIES | SERVICE MANUAL
11. T-Series Platform DSP Rescue Procedure
2. Connect the PC to the amplier via ETH port
3. Set the PC IP address as 192.168.5.1 like as
reported right. The subnet mask will be automatically
set.
4. Download the le “upgradet-v1.8.7.16.zip” into the
local PC
5. Power up the amp. with keep pressing the following
button
Note: The power up must be without pressing the
Standby push button
1. In the event when you not able to Boot Up your
Amplifer & having this Sceen Shot “Hanged”
6. The two push button must keep pressed for 8 sec.
until the front bar showed. If you keep pressed longer,
it’s no problem but while you keep pressed less than 8
sec. could be the problem that the rescue procedure will
Not Start.
In that case the all the procedure must repeat from the
beginning.
7. After this step the Display will show the IP address
192.168.5.200, more or less 15 sec. after the bar is
reached the end.