Page 24
Procedure 5.2 - Troubleshooting the Incline System
Incline System Description:
The incline system on these units consists of an A.C. line voltage driven incline motor (120 Vac or
240 Vac), and an internal 1 Kpotentiometer for incline position identification. The incline motor
contains two motor windings, one to operate the motor in an “upward” direction and the other to
operate the motor in a “downward” direction. As the incline motor is operated, the motor also
rotates the potentiometer via an internal gear system. Therefore, the position of the incline
system can be determined by monitoring the value of the internal potentiometer. The incline
motor is initially set at a known starting position (to set calibration, see Procedure 4.1),
subsequent motor movement is tracked via the potentiometer resistance reading.
Note:
All resistance measurements must be performed with power removed from the treadmill.
Performing resistance measurements with voltage applied may damage your ohmmeter.
Procedure
1. If the incline motor operates but creates a incline error (error 40 or 42) go to step 14. If the
incline motor will not move continue with step 2.
2. Set the treadmill’s on/off switch in the “on” position.
Diagram 5.3 - Power Control Module
3. With the incline below 15%, connect an A.C. voltmeter between terminals 1 & 6 of the
INCLINE connector. See Diagrams 5.3 and 5.4. Set the treadmill in the manual program and
press the INCLINE key. The A.C. voltmeter should read A.C. line voltage (either 120 Vac
or 240 Vac). Note that the A.C. line voltage reading will only be present before an error
condition is displayed.
Incline
Connector
Motor
Connector
Dynamic
Connector
Connector
A.C. Input
Connector
Data Cable
Braking

Other manuals for Precor C932i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Precor C932i and is the answer not in the manual?

Precor C932i Specifications

Power IconPower
motor power2.75 hp
power supply120 VAC (50/60Hz)
current15 Amps
Performance IconPerformance
speed range0.5 - 11 mph (1 - 18 kph)
incline range0 - 15% grade
Weight and Dimensions IconWeight and Dimensions
length79 in (201 cm)
width34 in (84 cm)
height55 in (140 cm)
weight280 lbs (126 kg)
shipping weight320 lbs (144 kg)
belt dimensions57 in x 20 in (145 cm x 51 cm)