100962 G PUBLICATION DATE 24 JUN 2008.DOC PROGRAMMING MANUAL 49
Insert the desired speed value. Press the ENTER button for
confirmation.
If you don‘t want to get into the supply sub-menu, press the
ARROW DOWN button.
Press the ENTER button to get into the supply sub-menu.
Default: all the supplies are switched off. (time = 0)
Liquid soap supplies can only be programmed if the selection
in the configuration menu is enabled.
The supplies can be programmed for an interval time
between 0 and 99 seconds.
The supply will not be activated if 0 Seconds is programmed.
You can program up to 4 supplies at the same time.
If you have programmed more then 4 supplies an error
message will be generated. Put the time of the supplies back
to zero until not more than 4 non-zero time values are
remaining.
The overview display shows the Supply Name and the
corresponding programmed time.
Insert the supply time. Press the ENTER button for confirmation.
At the end of the Menu, when EXIT is displayed, Press the
ENTER button to leave the supply Menu.
Attention
!
For Front Soap Hopper washing machines, the soap is
added by programming the supplies A to E. (X22/5 A to D)
External liquid soap pumps correspond with the supplies
F to K.
For Top Soap Hopper washing machines, the External liquid
Soap pumps correspond with the supplies D to J.
The number of external supplies that is available depends
on the machine type.
The wash motor ON time can be programmed between 0 and
99 seconds.
The wash motor OFF time can be programmed between 3
and 99 seconds.
The suggested default values can be adapted in the
Initialisation menu.
Standard wash motor ON time of 12 seconds and a wash
motor OFF time of 3 seconds is recommended for normal
wash. A wash motor ON time of 3 seconds and a wash motor
OFF time of 12 seconds is recommended for a gentle wash (woolens).
Insert the wished ON – OFF times. Press the ENTER button
FOR CONFIRMATION.
FS120, MB90, MB140, MB180 : 12Sec ON and 5Sec OFF
P:Pr XX Step XX
On Time : _ _ Sec
P:Pr XX Step XX
Off Time : _ _ Sec
P:Pr XX Step XX
Supply ?
P:Pr XX Step XX
Supply A: 0 Sec
P:Soap Supply
Menu Exit
!