100962 G PUBLICATION DATE 24 JUN 2008.DOC PROGRAMMING MANUAL 69
T THE LOW EXTRACT SEQUENCE
Only for washing machines with 2 motors.
Only available on washing machines with both : a normal
Open and a normal Closed Drain valve.
You can select Drain Valve 1 or 2.
The default Drain valve is Drain valve 1.
You have to select the desired a Drain Valve by pressing the
ARROW LEFT or RIGHT button.
Press the ENTER button for confirmation.
The Low Extract Sequence can be programmed between 0
and 9.5 minutes in steps of 0.5 minutes.
The default time is 1.0 Minute.
Programming a time of 0 minutes : the Low Extract part will
not be functional (cfr No Drain)
Insert the desired Low Extract sequence time.
Press the ENTER button for confirmation.
You can always return to a previous menu item by pressing
the ARROW UP button.
By pressing the ENTER button you will leave the current
Step. Goto } ®
Drain
|
Extract
|
Low Extract
|
Hi
g
h Extract
|
No Drain
|
Static Drain
P:Pr XX Step XX
Drain valve : 1
P:Pr XX Step XX
Time : 1,0 Min
P: Program
Ste
p
XX Exit