70 PROGRAMMING MANUAL 100962 G PUBLICATION DATE 24 JUN 2008.DOC
T THE HIGH EXTRACT SEQUENCE
Only for washing machines with 2 motors.
Only available on washing machines with both : a normal
Open and a normal Closed Drain valve.
You can select Drain Valve 1 or 2.
The default Drain valve is Drain valve 1.
You have to select the desired a Drain Valve by pressing the
ARROW LEFT or RIGHT button.
Press the ENTER button for confirmation.
The High Extract Sequence can be programmed between 0
and 9.5 minutes in steps of 0.5 minutes.
The default time is 4.5 Minutes.
Programming a time of 0 minutes : the High Extract step will
not be functional (cfr No Drain)
Insert the desired High Extract sequence time.
Press the ENTER button for confirmation.
You can always return to a previous menu item by pressing
the ARROW UP button.
By pressing the ENTER button you will leave the current
Step. Goto } ®
T THE NO DRAIN SEQUENCE
The Drain/Extraction part of the programmed step is skipped.
Attention !!!
For some specific functions “No Drain” must be programmed.
Example:
If you want to program a Cool-down Sequence, then “No Drain” must be programmed between the Hot Wash
and the Cool-down Sequence.
You can always return to a previous menu item by pressing
the ARROW UP button.
By pressing the ENTER button you will leave the current
Step. Goto } ®
Drain
|
Extract
|
Low Extrac
t
|
Hi
g
h Extract
|
No Drain
|
Static Drain
Drain
|
Extract
|
Low Extrac
t
|
Hi
g
h Extrac
t
|
No Drain
|
Static Drain
P:Pr XX Step XX
Drain valve : 1
P:Pr XX Step XX
Time : 4,5 Min
P: Program
Ste
p
XX Exit
P: Program
Ste
p
XX Exit