96 PROGRAMMING MANUAL 100962 G PUBLICATION DATE 24 JUN 2008.DOC
E57 Door Locked
Door Lock Switch stays
closed when the outer
door is open.
Don’t Start At locking sequence
(MB90-140-180 only)
E80
Time Out Input16
On Hold Signal Failure
Soap Dispensing
System
Full stop + tumble. Whole cycle
E81
No Reheat Heating Failure Full stop + tumble.
Wash Step
(MB only)
E82
No Refill
Refill failure
Full stop + request for
Continue
Wash Step
(MB only)
E83
Cycle Fail
No successful wash
cycle termination
Info that the wash cycle
has to be repeated.
Abnormal Cycle Termination
(MB only)
E84
No Store PC
Communication failure
with PC
For Info only. End cycle
(MB only)
E85
RTC Low Batt
Real Time Clock, No
Battery or battery low
power
For Info only. End cycle
(MB only)
E86
No RTC Comm
Real Time Clock is not
available
For Info only. End cycle
(MB only)
E150-
E165
Memory Err Memory Error Full stop + safety time Any time
E170-
E199
Softw Err Software Error Full stop + safety time Any time
E100-
E140
Mits Err Specific Mitsubishi
Inverter Alarm
Full stop + safety time Whole cycle

Table of Contents