100962 G PUBLICATION DATE 24 JUN 2008.DOC PROGRAMMING MANUAL 71
T THE STATIC DRAIN SEQUENCE
The drum is at standstill while the water is drained.
Only available on washing machines with both : a normal
Open and a normal Closed Drain valve.
You can select Drain Valve 1 or 2.
The default Drain valve is Drain valve 1.
You have to select the desired Drain Valve by pressing the
ARROW LEFT or RIGHT button.
Press the ENTER button for confirmation.
The Drain Sequence can be programmed between 0 and 9,5
minutes in steps of 0,5 minutes.
The default time is 0,5 Minutes.
Programming a time of 0 minutes : the Drain part will not be
functional (cfr No Drain)
Insert the desired Drain sequence time. Press the ENTER
button for confirmation.
You can always return to a previous menu item by pressing
the ARROW UP button.
By pressing the ENTER button you will leave the current
Step. Goto } ®
Attention !!!
It’s not recommended to program a spin sequence just after a Static Drain Sequence.
At a Static Drain sequence, the garments are not distributed around the drum while the water is drained.
When the spin sequence starts, the garments are a big imbalance and the imbalance (tilt) function will be
activated.
Drain
|
Extract
|
Low Extrac
t
|
Hi
g
h Extrac
t
|
No Drain
|
Static Drain
P:Pr XX Step XX
Drain valve : 1
P:Pr XX Step XX
Time : 0,5 Min
P: Program
Ste
p
XX Exit