EasyManuals Logo

Pro1 Technologies T855iSH User Manual

Pro1 Technologies T855iSH
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
T855iSH
Installation Manual
Pro1 Technologies
Toll Free: 888-776-1427
Web: www.pro1iaq.com
Hours of Operation: M-F 9AM - 6PM Eastern
Thermostat Application Guide
Description
Gas or Oil Heat
Electric Furnace
Heat Pump (No Aux. or Emergency Heat)
Heat Pump (With Aux. or Emergency Heat)
Multi-Stage Systems
Heat Only Systems
Cool Only Systems
Millivolt
Yes
Yes
Yes
Yes
Yes
No
Power Type
Hardwire (Common Wire)
Table of Contents
Installation Tips
Thermostat Quick Reference
Wiring
Wiring Diagrams
Technician Setup Menu
WIFI Tech Settings
Setting Humidity
Programming
Features
Remote Sensor Operation
Specications
Page
A trained, experienced
technician must install this
product.
Carefully read these
instructions. You could damage
this product or cause a
hazardous condition if you fail
to follow these instructions.
Una version en espanol de este
manual se puede descargar en
la pagina web de la compania.
Rev. 2028
U.S. Registered Trademark. Patents pending
Copyright 2020 All Rights Reserved.
5-8
15-33
1
2-4
Yes
Yes
34
Mount Thermostat
Align the 4 tabs on the subbase with
corresponding slots on the back of the
thermostat, then push gently until the
thermostat snaps in place.
Installation Tips
2
Note: To ensure a solid t between the
thermostat and the subbase:
1. Mount subbase to a at wall
2. Use screws provided
3. Drywall anchors should be ush with the wall
4. Wires should be pushed into the wall
Installation Tips
The thermostat should be installed approximately 4 to 5 feet above the
oor. Select an area with average temperature and good air circulation.
• Close to hot or cold air ducts
That are in direct sunlight
With an outside wall behind the thermostat
• In areas that do not require conditioning
Where there are dead spots or drafts (in corners or behind doors)
Where there might be concealed chimneys or pipes
Wall Locations
Pick an installation location that is easy for the user to access. The temperature
of the location should be representative of the building.
Installation Tip
Do not install thermostat in these locations:
3
4
Installation Tips
35-37
Vertical Mount
Horizontal Mount
For horizontal mount put one screw on
the left and one screw on the right.
All of our products are mercury free. However, if the product you are
replacing contains mercury, dispose of it properly. Your local waste
management authority can give you instructions on recycling and
proper disposal.
Mercury Notice
Failure to disconnect the power before beginning to install this product
can cause electrical shock or equipment damage.
Installation Tip: Electrical Hazard
For vertical mount put one screw on
the top and one screw on the bottom.
Subbase Installation
11-14
9-10
Wired Remote Sensing
Yes
P.O. Box 3377
Springeld, MO 65808-3377
Any HVAC system up to 5H/3C with
standard low voltage controlled humidier.
Any HVAC system up to 5H/3C with standard
low voltage controlled de-humidier.
Yes
Yes
44
45
38-43
46

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pro1 Technologies T855iSH and is the answer not in the manual?

Pro1 Technologies T855iSH Specifications

Temperature Control IconTemperature Control
display temperature range41˚F to 95˚F (5˚C to 35˚C)
control temperature range44˚F to 90˚F (7˚C to 32˚C)
swing heating adjustment0.2˚ to 2.0˚
swing cooling adjustment0.2˚ to 2.0˚
Power IconPower
load rating per terminal1 amp
maximum load rating all terminals combined1.5 amp
power source18 to 30 VAC, NEC Class II, 50/60 Hz
power source current500 mA
Operating Environment IconOperating Environment
operating ambient temperature32˚F to +105˚F (0˚C to +41˚C)
operating humidity90% non-condensing maximum
frequency range2.4 GHz ISM radio band
Weight and Dimensions IconWeight and Dimensions
width4.7”
height4.3”
depth0.9”

Related product manuals