OPERATION
PEAK 86037220 05/22/08
3-5
1. WASTE TANK FULL INDICATOR LIGHT
This indicator light is activated when the waste
tank is full. When lit the unit will shutdown
protecting the equipment from damage. This
also indicates that the waste tank must be
emptied before the unit can be brought back in
service.
NOTE: Never dispose of waste water in
storm drains, water ways or on ground
areas. Always dispose of waste in
accordance with local state and federal laws.
2. ENGINE HIGH TEMPERATURE SHUTDOWN
INDICATOR
This light when activated signals an over heat
condition with the engine. When this occurs,
troubleshooting is required.
3. VACUUM GAUGE
This gauge indicates in inches of mercury how
much vacuum the system is producing at any
given time.
4. SOLUTION PRESSURE GAUGE
This gauge registers the amount of pressure in
the system.
5. BYPASS VALVE
This valve allow the operator to control the
solution temperature by bypassing hot water to
the waste tank, for low temperature cleaning
such as upholstery. Turning the valve counter
clockwise opens the valve. Turning clockwise
closes the valve and has the effect of stopping
water from bypassing.
6. SOLUTION TEMPERATURE GAUGE
This gauge measures the temperature of the
cleaning solution as it exits the machine.
7. WASTE PUMPOUT AND AUXILIARY WATER
PUMP SWITCH
This four-position switch is for activating the
waste pumpout device. It also serves to activate
the fresh water transfer pump. For turning on
pumps, rotate clockwise. For turning off pumps,
rotate counter clockwise.
8. CHOKE
The choke cable is for restricting air to the
carburetor, this enriches the fuel mixture. The
primary purpose is for starting in cold
temperatures. When the cable is pulled out air
is restricted, when pushed in the engine is in run
position.
9. SOLUTION PUMP SWITCH
This switch serves to energize the magnetic
clutch to turn the water pump on or off. Turn
clockwise for activating the pump and counter
clockwise for deactivating the pump.
10. KEY SWITCH
The key switch controls the power for the
machine. To turn the machine on, rotate the
key clockwise while holding solution pump
switch to override position until the starter
engages the engine. When machine is running
let off the switch and engine will continue to run.
To turn power off, rotate key counter clockwise
to stop position, engine will then stop.
11. THROTTLE
This serves to set the speed of the engine.
Handle pushed in sets engine to idle. Handle
pulled out sets engine speed to maximum.
Handle clockwise to lock in position and counter
clockwise to move or change throttle settings.
12. CIRCUIT BREAKERS
These serve to protect the circuits from
electrical spike and over loads and protects
wires from damage and fire.
13. HOUR METER
The hour meter records the number of hours the
unit has run. This serves as a time recorder for
servicing the machine.