EasyManua.ls Logo

Procom MN100HBG - User Manual

Default Icon
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
VENT-FREE GAS WALL HEATER
OWNER’S OPERATION AND
INSTALLATION MANUAL
BLUE FLAME
30,000 BTU/Hr
Model Shown
Questions, problems, missing parts? Before returning to your retailer, call
our customer service department at 1-866-573-0674, 8:00 am - 4:30 pm CST,
Monday through Friday or email contact@usaprocom.com
MODELS
M(N,L)100HBG, M(N,L)100TBG
M(N,L)200HBG, M(N,L)200TBG
M(N,L)300HBG, M(N,L)300TBG
WARNING: If the information in this manual is not
followed exactly, a re or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other ammable va-
pors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas suppliers instructions.
If you cannot reach your gas supplier, call the re
department.
Installation and service must be performed by a quali-
ed installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
CSA/ANS
Z21.11.2 2019
Unvented
Room Heaters

Questions and Answers

  • L
    Leslie BishopSep 9, 2025
    Why is my Procom MN100HBG clicking?
    • M
      Mark LawsonSep 9, 2025
      If your Procom Heater produces a clicking/ticking noise just after the burner is lit or shut off, it is likely due to the metal expanding while heating or contracting while cooling. This is common with most heaters. If the noise is excessive, contact a qualified service technician.
  • G
    Gregory FloresSep 12, 2025
    Why is there a delay when my Procom MN100HBG Heater ignites?
    • K
      Kelly NormanSep 12, 2025
      If you experience delayed ignition of burner(s) in your Procom Heater, it could be due to low manifold pressure, which requires contacting your local gas supplier. Alternatively, the burner orifice might be clogged, so clean the burner or replace the burner orifice.
  • C
    Cameron ReyesSep 12, 2025
    What to do if my Procom Heater sparks but doesn't ignite?
    • J
      Jonathan HarrisSep 12, 2025
      If the ignitor button is pressed and there is a spark at the ODS/pilot, but no ignition occurs on your Procom Heater, first ensure the gas supply is turned on and the equipment shutoff valve is open. Also, make sure the control knob is fully pressed in while pressing the ignitor button. If there is air in the gas lines from installation, continue holding down the control knob and repeat the igniting operation until the air is removed. A clogged ODS/pilot can also cause this; clean or replace the ODS/pilot assembly. Check the inlet gas pressure or replace the inlet gas regulator if needed. Ensure the control knob is in the PILOT position, and if you are using propane, check for a depleted gas supply and contact your local propane gas company.
  • T
    Tracy WilsonSep 15, 2025
    Why is there white powder around my Procom Heater?
    • P
      Paige HunterSep 15, 2025
      If white powder residue is forming within the burner box or on adjacent walls or furniture near your Procom Heater, it is likely due to vapors from furniture polish, wax, carpet cleaners, etc., turning into white powder residue when heated. To prevent this, turn off the heater when using such products.
  • I
    irobinsonSep 17, 2025
    Why do I smell gas when using my Procom Heater?
    • A
      Aaron GilbertSep 17, 2025
      If you notice a gas odor during combustion with your Procom Heater, it could be due to foreign matter between the control valve and burner, so take apart the gas tubing and remove any foreign matter. Alternatively, there could be a gas leak, so locate and correct all leaks.