EasyManua.ls Logo

Profitec Pro 600 - 6.2 Manual Adjustment of the Brewing Pressure; PID CONTROLLER FUNCTIONS; Setting Boiler Temperatures

Profitec Pro 600
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENGLISH
Bedienungsanleitung / Instruction manual Profitec PRO 600 - I 24
It is recommended to leave the portafilter in the brew group, keeping it warm for optimum
temperature for coffee dispension.
6.2 Manual adjustment of the brewing pressure
You can individually adjust and change the brewing pressure by turning the adjusting screw, choosing a
value between approx. 8.5 and 12 bar.
To adjust the brewing pressure, proceed as follows:
1. Remove the Drip tray.
2. Place the portafilter with the blind filter (filter without holes) into the brew group.
3. Operate the group lever and read pressure at the pump pressure gauge.
4. Choose the desired brewing pressure by turning the adjusting screw with a coin or a flat screwdriver.
You can reduce the brewing pressure by turning the screw anti-clockwise and increase it by turning it
clockwise.
5. You can read the programmed pump pressure on the pump pressure gauge.
6. Replace the Drip tray. Now place the group lever back into the lower position to stop brewing. Unclamp
the portafilter and replace the blind filter with a coffee filter.
7. Now the machine is ready for use again.
6.3 PID-display functions
The following explains the different programming options of PID control.
6.3.1 Programming the temperature of both boilers
During normal operations, the temperatures of the coffee boiler (t1, period in the 1st position) and the steam
boiler (t2, period in the 2st position) are indicated alternately.
The controls are factory pre-set so that both boilers are heated consecutively, whereby the coffee boiler (t1)
has priority. This means that the steam boiler (t2) is activated only after the programmed temperature of the
coffee boiler has been reached.
1. Switch the machine on in order to activate both boilers (switch in
position “2”). The temperature of either boiler is of no importance in
programming. Both heaters are inactive during programming.
2. Press + and at the same time until ‘t1’ (coffee boiler) appears on
the display,
3. Press + in order to progress to the submenu of ‘t1’ and to change the
temperature value. The nominal temperature value is displayed.
4. Quickly press
to decrease
+ to increase
the nominal temperature value.

Table of Contents

Related product manuals