EasyManuals Logo

ProMinent Sigma/ 1 Basic S1Ba User Manual

ProMinent Sigma/ 1 Basic S1Ba
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #14 background imageLoading...
Page #14 background image
WARNING!
ATEX pumps and flammable media
Only with material versions PP_, PV_ and PC_: The igni‐
tion temperature is reduced significantly below the igni‐
tion temperature at atmospheric pressure due to com‐
pression with the discharge stroke of the possibly
ignitable vapour-air mixture.
Do not allow it to run dry. Take appropriate protec‐
tive measures.
Immediately switch off the pump in the event of a
diaphragm rupture.
WARNING!
ATEX pumps in areas at risk from explosion
If feed chemicals are metered, which tend to produce
exothermic reactions or self-ignite (examples of exo‐
thermic reactions: pyrophoric substances with air, alkali
metal with water, decomposition of organic peroxides,
polymerisation reactions), they can lead to high tempera‐
tures and ignition.
Put in place measures in accordance with EN
1127-1.
WARNING!
ATEX pumps in areas at risk from explosion
If abrasive media are being metered, they will escape as
soon as all layers of the diaphragm have eroded
through.
Wire the electrical diaphragm rupture indicator to
stop the pump in the event of a diaphragm rupture.
WARNING!
ATEX pumps in areas at risk from explosion
Electrically wire all electrical units cleanly and per‐
manently to an electrically clean earthing point, -
e.g. with an earthing bar on your system.
Electrically connect the electrical units fitted with a
potential equalisation cable to each other, cleanly
and permanently, to an electrically clean potential
equalisation point - e.g. with a potential equalisation
bar on your system.
Note the enclosed documentation for the individual
electrical components.
WARNING!
ATEX pumps in areas at risk from explosion
Use a suitable motor protection switch to protect
power end motors. Use motor protection approved
for this application with Ex"e" motors. (Protection
against warming caused by overloading)
Provide a time-delay residual current device.
Observe the enclosed operating instructions for the
Ex motor.
Safety chapter
14

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ProMinent Sigma/ 1 Basic S1Ba and is the answer not in the manual?

ProMinent Sigma/ 1 Basic S1Ba Specifications

General IconGeneral
BrandProMinent
ModelSigma/ 1 Basic S1Ba
CategoryWater Pump
LanguageEnglish

Related product manuals