Identity code
specification
Phases, protec‐
tion
Rated voltage Mains frequency Rated output Remarks
N 1-phase AC, IP
55
115 V ±5% 60 Hz 0.12 kW
L1 3-phase,
II2GEExeIIT3
220-240 V /
380-420 V
50 Hz 0.12 kW
L2 3-phase,
II2GEExdIICT4
220-240 V /
380-420 V
50 Hz 0.18 kW with PTC, speed
control range 1:5
P1 3-phase,
II2GEExeIIT3
250-280 V /
440-480 V
60 Hz 0.12 kW
P2 3-phase,
II2GEExdIICT4
250-280 V /
440-480 V
60 Hz 0.18 kW with PTC, speed
control range 1:5
Motor data sheets, special motors, special motor
flanges, external fan, temperature monitoring
For further information on the motor with identity
code specification "S", refer to our website
www.prominent.com. Motor data sheets can be
requested for all other motors.
With motors other than those with identity code
specifications "S", "M" or "N": Pay special attention
to the operating instructions for the motors.
Special motors or special motor flanges are avail‐
able on request.
15.8 Stroke actuator
Voltage Mains frequency Capacity
230 V ±10% 50/60 Hz 11.7 W
115 V ±10 % 60 Hz 11.7 W
15.9 Stroke control drive
Voltage Mains frequency Capacity
230 V ±10% 50/60 Hz 6.5 W
115 V ±10 % 60 Hz 6.5 W
15.10 Diaphragm rupture sensor
Install the sensor according to the chapter "Installation,
electrical".
Tab. 3: Contact loading, max.
with voltage Maximum current
30 V DC 1 A
a) Contact (Standard with identity code
specification "Displacement body“: A)
Technical data