Data Value Unit
Max. temperature, long-term at max. oper‐
ating pressure
90 °C
Max. temperature, for 15 min at max. 2 bar 120 °C*
Minimum temperature -10 °C
* not in areas at risk from explosion
15.5.3
Air humidity
Data Value Unit
Maximum air humidity*: 92 % relative
humidity
*non-condensing
15.6
Installation height
Data Value Unit
Maximum installation height*: 1000 m above
standard
zero
* with standard pumps: Fit at higher installation heights at your own risk.
with ATEX pumps: We urgently advise that you contact a specialist for
ATEX motors at higher installation heights!
15.7
Motor data
Identity code
specification
Phases, protec‐
tion
Rated voltage Mains frequency Rated output Remarks
S 3-phase, IP 55 220-240 V /
380-420 V
50 Hz 0.09 kW
265-280 V /
440-480 V
60 Hz 0.09 kW
T 3-phase, IP 55 220-240 V /
380-420 V
50 Hz 0.09 kW with PTC, speed
control range 1:5
265-280 V /
440-480 V
60 Hz 0.09 kW
R 3-phase, IP 55 230 V/400 V 50 Hz 0.09 kW with PTC, speed
control range
1:20, with
external fan 1-
phase 230 V;
50/60 Hz
V0 1-phase AC, IP
55
230 V ±10% 50/60 Hz 0.18 kW Variable speed
motor with inte‐
grated frequency
converter
M 1-phase AC, IP
55
230 V ±5% 50/60 Hz 0.12 kW