16 Diagrams for Setting the Capacity
C [l/h]
C [l/h]
S [%]
p [bar]
p [bar]
p [bar]
S [%]
S [%]
0.0
10.0
20.0
30.0
40.0
50.0
60.0
10050
12035 *
12017 *
0.0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
0.0 2.0 4.0 6.0 8.0 10.0 12..0
10050
12035 *
12017 *
S1Ba (50 Hz)
A
B
0 10 20 30 40 50 60 70 80 90 100
0 10 20 30 40 50 60 70 80 90 100
C [l/h]
C [l/h]
S1Ba (50 Hz)
A
B
C [l/h]
C [l/h]
S1Ba (50 Hz)
A
B
0 10 20 30 40 50 60 70 80 90 100
0.0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
07065
10044
10022
0.0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10. 11.0
07065
10044
10022
0.0
20.0
40.0
60.0
80.0
100.0
120.0
140.0
160.0
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0
04120
04084
07042
0.0
20.0
40.0
60.0
80.0
100.0
120.0
140.0
04120
04084
07042
Fig. 25: A) Capacity C at minimum back pressure dependent on the stroke length s. B) Capacity C dependent on the
back pressure p. * 12 bar only for SST!
Diagrams for Setting the Capacity
67

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ProMinent Sigma/ 1 Basic S1Ba and is the answer not in the manual?

ProMinent Sigma/ 1 Basic S1Ba Specifications

General IconGeneral
BrandProMinent
ModelSigma/ 1 Basic S1Ba
CategoryWater Pump
LanguageEnglish

Related product manuals