Data Value Unit
Output 220 W
Max. starting current 8.5 A
Electrical data at 100 V
Data Value Unit
Effective current 3.3 A
Switch on peak current, (for approx. 100
ms)
4 A
Electrical data at 230 V
Data Value Unit
Effective current 1.5 A
Switch on peak current, (for approx. 100
ms)
8 A
* internal switchover
Tab. 14: Fuses
Fuse Value Order no.
Fuse, internal 6.3 AT - (1.5 kA) 732379
INFORMATION!: Only use the original ProMinent fuses. It is not sufficient
to use a fuse with the above fuse rating.
16.8
Diaphragm rupture sensor
Tab. 15: Contact loading, max.
at voltage Maximum current
30 V DC 1 A
The contact is an opener.
The contact is an potential-free.
–
For safety reasons we recommend connecting to a
protective low voltage, e.g. in accordance with EN
60335-1 (SELV ).
–
The cable can be poled as required.
5–25 V DC, in accordance with Namur or DIN 60947-5-6, potential-free
design.
Specification Value
Nominal voltage * 8 V DC
Power consumption - active surface uncovered > 3 mA
Power consumption - active surface covered < 1 mA
Rated switching distance 1.5 mm
* Ri ~ 1 kΩ
Contact (standard)
Namur sensor (Specified for EX zones)
Technical data
86