6
Installation of the machine
Good Ventilation
The distance between the machine and the wall or other objects nearby should be
between 200mm and 500mm. The ventilation of the machine should be free flowing
and free from dust or other particles. The condenser outlet is located to the left or the
back of the machine so the space in these areas should be as large as possible to
allow hot air to be naturally ventilated away without obstruction. (Diagram 4)
Avoid small spaces and ensure good ventilation around the machine at all times.
Avoid small enclosed areas.
Diagram 4
Environment
The machine should be located in a dry environment where the air humidity should
not exceed 80% and the altitude does not exceed 2000m.
The ideal temperature around the machine is between 10°C to 30°C.
Avoid using the machine in direct sunlight or in wet conditions. Never let water or ice
cream/yogurt mix inside the mechanics at the rear of the machine.
Avoid operating close to caustic gas or heavily contaminated/dirty areas.
The location of the machine should be rodent and pest free.
Power Supply/Earth Connection
The power plug fitted to the machine should always be checked to ensure it satisfies
industry standards when in its final location.
Ensure a qualified electrician provides a dedicated circuit for the machine with a
circuit breaker and, if required, an ampage regulator. Do not share the power
supply/circuit with other appliances as this will severely affect the performance of
the machine.
If this machine is not fitted in the UK, please ensure the machine is properly earthed
before use. The yellow-green earthing wire should be connected to the metal
cabinet of the machine with the other end earthed by an electrician.