Model # PT 45-KFA PT 70T-KFA PT 125T-KFA PT 175T-KFA PTH-215T-KFA
Rating BTU/Hr 45,000 70,000 125,000 175,000 215,000
Fuel Consumption Gal/Hr 0.35 0.53 0.95 1.33 1.63
Fuel Tank Capacity
Gallons
5.0 5.0 10.0 13.0 13.0
Pump Pressure PSI 3.0 4.0 5.0 7.5 9.0
Volt/Hz 120VAC/60 Hz 120VAC/60 Hz 120VAC/60 Hz 120VAC/60 Hz 120VAC/60 Hz
Amps 1.4 1.5 2.3 2.7 2.8
Phase
Single
Single Single Single Single
Size (L x W x H) 30” x 12” x 15” 30” x 12” x 15” 38” x 22” x 25” 43” x 24” x 26” 43” x 24” x 26”
Weight (Lbs) 32 32 60 67 72
Page 4 Pinnacle Products International, Inc. Kerosene Owners Manual
Figure 4. Product Dimensions
Specifications subject to change without notice
Never leave heater
unattended while burning,
or while connected to a
power source
PT 175T-KFA
PT 215T-KFA
H 26”
L 43”
W 24”
PT 45/70T-KFA
H 15”
L 30”
W 12”
PT 125T-KFA
H 25”
L 38”
W 22”