Displaying and changing the values in the menus
29
Basic settings
menu
Position
Symbol Description Range Factory
settings
Current
settings
P: 7:
Pump runtime "Drain
-
back
" function
15
360
s
180
s
P: 8:
"Recooling" function
0 = Off
1 = On
Only if the "Collector protection"
function has been activated.
0–1 0
P: 9: Temperature to which the storage tank
is recooled.
Only if the "Collector protection" and
"Recooling" functions have been
activated.
30–90 °C 40 °C
P: 10:
"Tube collector" function
0 = Off
1 = Time
-
controlled
0–1 0
P: 11: "Tube collector" function: Pump
runtime
10–120 s 30 s
P: 12:
Measurement principle for
energy output measurement
0 = Off
3 = Flow indicator
0–3 0
P: 15: Flow rate for the "Flow indicator"
measurement principle
Unit: Litres per minute
Only if the "Flow indicator"
measurement principle has been
activated.
0.1–
75 litres/min
(in 0,1 litre
increments)
10,0 l
P: 16: Energy output measurement:
Glycol type *
0–10 0
P: 17: Energy output measurement:
Glycol concentration
0–100 %
(in 5 %
incremen
ts)
50
P: 18:
„Anti-freeze protection“ function
0 = Off
1 = On
0–1 0
P: 20: "Anti-freeze protection" function: Start
temperature
-20 – +7 °C 3 °C
P: 21:
MFC R1 function at switching
output R1
0 = Off
1 = Cooling
2 = Heating
3 = Temperature difference
controller
0–3 0
P: 22:
Select
ion of the sensor for the source
1
4
3