8. Maintenance and Care
8.1 Component Maintenance
Components Robot Status Inspection Interval Method
Drive wheels and
auxiliary wheels
Powered off One week Please wipe the surface with a
clean cloth. Check the wheel
surface for wear and replace if
necessary.
Visual sensor, and
LiDAR
Powered off One week Please wipe the surface with a
clean cloth.
If there is sudden dirt or damage,
please handle it in time to avoid
blocking the sensor and causing
abnormal operation of the robot.
Robot body Powered off One month Please wipe the surface with a
clean cloth. And check the
installation. Make sure the housing
is flat and securely fixed.
Indicator lights and
sound
Powered on One month Check that all indicator lights and
audible warnings are working
properly.
Emergency stop
switch
Powered on One month Check that the emergency stop
button is working properly.
Battery Charging Three months / Six
months
To avoid over-discharged state,
battery shall be charged
periodically to maintain 20~50%
of capacity. Built-in battery shall
be charged with terminal every 3
months while removable battery
shall be charged every 6 months
are recommended.
Brake switch Powered on Six months Put the brake switch to the "OFF"
position and gently push the robot
forward to check that the brake
switch is working properly.
Note: Turn the brake to the "ON"
again after checking.
Safety stickers and Powered off Six months Check that the safety stickers,