Echo Profile Overview
The Digital Adaptive Tracking of Echo Movement, is a powerful algorithm
unique to Pulsar’s ultra range of products. Care should always be taken when
adjusting and analysing echo profiles, if in doubt, please contact Pulsar technical
department.
There are no typical echo traces for Sludge Blanket applications, the echo
returns vary widely with the type of application and the concentration levels of the
Sludge.
The screen shot below is a Secondary Clarifier approx 70% full.
The y axis indicates signal strength and the x axis is distance.
The black shape is the echo profile of the sludge.
The blue line indicates the measuring point.