What to do if my Pulsar FlowCERT LITE Measuring Instruments display shows an incorrect reading for the current level?
M
Michael JohnsonJul 31, 2025
If your Pulsar Measuring Instruments display is showing an incorrect reading for the current level, measure the actual distance from the transducer head to the surface of the material. Then, enter Program Mode and directly access P21 (Set Distance). Type in the measured distance, press ENTER, and then ENTER again when prompted. Wait until SET is displayed and return to Run Mode; the display should now update to the correct reading.
J
Janet FoxAug 4, 2025
Why are the LEDs changing color at relay switch points, but the relays don't change state on my Pulsar Measuring Instruments?
M
Marcus OrtegaAug 4, 2025
If the LEDs on your Pulsar Measuring Instruments are changing color at the relevant relay switch points, but the relays are not changing state, check the power supply to the unit and ensure that the voltage selector is set to the correct position.
R
Rebecca CummingsAug 8, 2025
What to do if my Pulsar FlowCERT LITE display shows 'Xducer Flt'?
A
Amy RodgersAug 8, 2025
If your Pulsar Measuring Instruments display shows 'Xducer Flt', it indicates a fault with the transducer wiring. Check the wiring to the transducer to resolve this issue.
D
Deanna ChapmanAug 13, 2025
What to do if my Pulsar FlowCERT LITE display shows 'No Xducer'?
V
Victoria McdowellAug 13, 2025
If your Pulsar Measuring Instruments display shows 'No Xducer', check the wiring to the transducer.
L
Laura HerreraAug 17, 2025
How to troubleshoot a consistently incorrect material level on Pulsar FlowCERT LITE?
S
Shannon StewartAug 17, 2025
To troubleshoot a consistently incorrect material level on your Pulsar Measuring Instruments, check the empty level (P105), display offset (P802), and measurement offset (P851).
J
Jennifer MurphyAug 21, 2025
What to do if my Pulsar Measuring Instruments display is blank and the transducer isn't firing?
K
Kevin CostaAug 21, 2025
If the display on your Pulsar Measuring Instruments is blank and the transducer isn't firing, check the power supply, voltage selector switch, and fuse.
A
Ashley BellAug 26, 2025
What to do if my Pulsar FlowCERT LITE Measuring Instruments display shows 'ExTemp.Open'?
E
erikthomasAug 26, 2025
If your Pulsar Measuring Instruments display shows 'ExTemp.Open', it means the external temperature sensor is not detected. Check the wiring or change P852 (Temp Source).