Pi HSC816 Installation Manual - Revision Beta
This document and product are copyrighted and all rights are reserved.
14
Bottom row of status LEDs indicate data present in a location.
A flashing ready LED indicates that the panel is in a programming mode.
Binary values:
Zone LED 1 2 3 4 5 6 7 8 9 10
Binary value 1 2 4 8 16 32 64 128 256 512
Status LEDs Arm Home1 Instant AC/LB
Binary value 1 2 4 8
Add the binary values that are lit together to obtain question number or data value.
Hexadecimal values:.
Pressing the ARM key followed by digits 1 to 6 will give data value A to F and indicated by value 10 to 15.
Arm 1 = A data representation 10
Arm 2 = B data representation 11
Arm 3 = C data representation 12
Arm 4 = D data representation 13
Arm 5 = E data representation 14
Arm 6 = F data representation 15
Exiting program mode:
Press and hold the HOME key. All LEDS will flash for approximately 15 seconds, then return to normal.
Programming levels:
Level 1 = Keypad programming.
All system programming functions are carried out in this level.
Level 2 = Wireless detector programming. (see page 11 for procedure )
Level 3 = Default user codes only
Level 4 = Reserved.
Level 5 = Reserved.
Level 6 = Reserved.
Level 7 = Reserved.
Level 8 = Reserved.
Zone Programming:
Controlled Zones:
Entry/Exit - This zone type is the primary entry and final exit point into the premises. Violation of
an entry point when system armed will only start the entry timer. If a valid code is not
entered within the entry time an alarm condition will occur.
Follower - A follower zone becomes an entry / exit zone during a valid entry / exit procedure. If
the zone is violated outside an entry / exit timer, the zone then acts as an instant
zone.
Instant audible - This zone type when activated will cause an instant alarm condition with siren and
communicator activation.
Instant silent - This zone type when activated will cause an instant alarm condition without any
siren activation but with communicator.
Keypad buzzer - This zone type when activated will activate the keypad buzzers only, no siren or
communicator.
24 Hour Zones: (armed or disarmed)
24-hour audible - This zone type when activated will cause an instant alarm condition with siren
and communicator.