Page #48 background imageLoading...
Page #48 background image
LED Status Description
System Status Flashes green and red alternately
every 0.5 seconds
The drive is being formatted.
The device is being initialized.
The operating system is being
updated.
RAID rebuilding is in progress.
Online RAID Capacity
Expansion is in progress.
Online RAID Level Migration is
in progress.
Red The drive is invalid.
The disk volume has reached
its full capacity.
The disk volume is about to
reach its full capacity.
The system fan is not
functioning.
An error occurred when
accessing (read/write) the
data.
A bad sector is detected on
the hard drive.
The device is in degraded
read-only mode (two member
drives failed in RAID 5 or
RAID 6 but the data can still
be read).
A hardware self-test error
occurred.
Flashes red every 0.5 seconds The device is in degraded mode
(one member drive failed in RAID
1, RAID 5, or RAID 6).
Flashes green every 0.5 seconds The device is not configured.
A drive is not formatted.
Green The device is ready.
Off All drives are in standby mode.
TS-x32PXU User Guide
Basic Operations 47

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the QNAP TS 32PXU Series and is the answer not in the manual?

QNAP TS 32PXU Series Specifications

General IconGeneral
BrandQNAP
ModelTS 32PXU Series
CategoryStorage
LanguageEnglish

Related product manuals