SECURITY AND ARMING
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE OF 44 197
PROGRAMMING
Setting
Default
Description
Arm Stay - No Delay
Enabled
Arm stay immediately with no countdown timer
Auto Exit Time Extension
Enabled
Automatically extend countdown timer if delay door is opened during countdown process a
second time
Keyfob Instant Arming
Enabled
When enabled, turns off exit delay if keyfob is used to arm the system
Keyfob Alarm Disarm
Disabled
When enabled this will Allow a keyfob to disarm alarm events.
Keyfob Disarming
Enabled
When Disabled, a Keyfob will not be able to disarm the panel
Engineers Reset
Disabled
If a confirmed alarm occurs on a burglary zone, the system is locked out after disarming until a 5
digit reset code provided by the installer is entered in.
Allow Master Code to Access
Security and Arming
Disabled
Allow the master code to access these features and settings.
NOTE: this option shall be disabled for UL/cUL. This option shall be enabled for UL Commercial Burg installations.
Normal Entry Delay
30 Secs
How much time users have to enter their code after opening a door (30-240secs). With SIA limits
disabled the minimum time can be set to 5 secs.
NOTE: For UL Commercial Burg (UL2610) maximum entry delay should not exceed 60s. For EN Grade 2 it shall not exceed 30 sec.