Setting
Default
Description
Panel Sirens
All Sirens
On
All Sirens Off: This will disable the siren for all alarm types, except
for life safety devices, including any hardwire or wireless external
sirens.
All Sirens On: This is the default setting which enables the siren
for all alarms
Installer/Test Mode: This disables the siren for all alarm types
including any paired or hardwired external sirens for 30 mins then
all sirens are re-enabled
Siren Annunciation
Disabled
Panel siren pauses periodically to announce which locations have
triggered the alarm.
NOTE: for UL/cUL this feature is not allowed for Fire, CO, Burglar Alarm
Fire Verification
Disabled
When enabled, panel requires two fire events from smoke
detector (one detector twice or two detectors once each)
NOTE: Not allowed on UL/cUL installations
SIREN AND ALARMS
FIND IT
SIREN AND ALARMS
Siren and Alarms
Change siren and alarm settings for certain types of alarm events.
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE OF 39 197
Swipe down
for access
INSTALLATION
SETTINGS
ADVANCED SETTINGS
ENTER CODE (1111, 2222)
PROGRAMMING