Burglary Alarm Confirmation
When enabled, a confirmed alarm requires two sequential burglary alarms within the
Burglary Alarm Confirmation Timer window. NOTE: This setting is greyed out and unavailable unless EN
Grade 2 is enabled.
Burglary Alarm Confirmation Timer
Timer used for Burglary Alarm Confirmation. NOTE: This setting is greyed out and unavailable unless EN
Grade 2 is enabled.
Severe Weather Siren Warning
When enabled, siren will sound when the panel receives a severe weather alert. When
disabled, panel will use severe weather chime
Dialer Delay
NOTE: Shall not be used on EN Grade 2
Amount of time (in seconds) before panel will attempt call to central station after an alarm
event is triggered
When SIA Limits enabled: :15 to :45 seconds
When SIA Limits disabled: :0 to :254 seconds
Determine how long before siren stops sounding during an alarm event (3 minutes to 15
minutes). NOTE: For UL/cUL residential fire/burg applications the minimum bell timeout shall be set to 5 min. For
UL Commercial Burglary installations, minimum bell time out shall be set to 15 minutes. For EN Grade 2 the minimum
bell timeout shall be 90 sec and maximum bell timeout shall not exceed local regulations.
Water/Freeze/Temperature Siren
When enabled, siren will sound when a water or freeze detector is triggered. When
disabled, the panel emits a āwaterā tone
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE OF 40 197