Page #42 background image
SECURITY AND ARMING
FIND IT
SECURITY AND
ARMING
Swipe down
for access
INSTALLATION
SETTINGS
ADVANCED SETTINGS
ENTER CODE (1111, 2222)
Security and Arming
Change arming settings, entry and exit delays, enable Duress Authentication
and more.
* Additional options available
only through the Dealer Code.
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE OF 42 197
PROGRAMMING
Setting
Default
Description
Dealer Code*
2222
Code to access all options
Installer Code
1111
Code to access installer options only
Swinger Shutdown
Enabled
Determines whether the panel allows the same sensor to trip the
alarm more than once during the same arming period. When Enabled,
the sensor will trip according the to the Swinger Shutdown Count
setting. When Disabled, a sensor may trip up to 128 times per arming
period.
Swinger Shutdown
Count
1
Determines the number of times the same sensor is allowed to trip the
alarm during the same arming period (1-6). Swinger Shutdown must
be enabled in order for this setting to work. NOTE: For EN Grade 2 it shall be set
to 3
Panel Tamper
Enabled
This setting enables or disables the Panel Tamper switch on the back of
the panel. NOTE: for UL/cUL and EN Grade 2 this setting shall be Enabled