Code to access all options
Code to access installer options only
Determines whether the panel allows the same sensor to trip the
alarm more than once during the same arming period. When Enabled,
the sensor will trip according the to the Swinger Shutdown Count
setting. When Disabled, a sensor may trip up to 128 times per arming
period.
Determines the number of times the same sensor is allowed to trip the
alarm during the same arming period (1-6). Swinger Shutdown must
be enabled in order for this setting to work. NOTE: For EN Grade 2 it shall be set
to 3
This setting enables or disables the Panel Tamper switch on the back of
the panel. NOTE: for UL/cUL and EN Grade 2 this setting shall be Enabled