Flow diagram, air circuit (compressors with integrated dryer)
Reference Description
1 Intake air
2 Air/oil mixture
3 Oil
4 Wet compressed air
5 Condensate
6 Dried compressed air
Description
Air drawn through inlet filter (AF) and open inlet valve (IV) of the unloader is compressed in
compressor element (E). A mixture of compressed air and oil flows into the air receiver/oil
separator tank (AR). The air is discharged through outlet valve (AV) via minimum pressure valve
(Vp) and air cooler (Ca).
The air cooler is provided with a moisture trap (MT).
On compressors with integrated dryer, the air flows through air dryer (DR) before it is discharged
through outlet valve (AV). Also see section Air dryer.