GRB-200 Demodulator (GOES-R) OI&M
GRB-200 Demodulator (GOES-R) OI&M
© Copyright 2015, Quorum Communications, Inc.
Revision A.01
12
Provide a minimum of 1U of space above and below the GRB-200 for
airflow/ventilation.
2.2 RACK USE
The GRB-200 is designed for installation in a standard 48-centimeter-wide rack
with a depth of 61 to 71 centimeters (19 x 24 to 28 inches). To mount the GRB-
200 in a rack, remove the four rubber foot pads and screws, and then attach the
rack supports using the fasteners shown in Figure 5. Mount the GRB-200 with
rack supports into the rack enclosure.
#8 8
/
32 x
3
/8
Screws
with split ring and
washer (7)
Figure 5 - Rack Mounting