7d
2.4 Reset
To restore the manufacturer’s settings
(standard values), a reset can be carried out
(g. 7a-d).
The above parameters are then reapplied,
and the drill width must be input.
How to carry out a RESET:
•When switching on, immediately keep the
lower left soft key <S1> (g. 8) pressed.
•Then conrm this with the <Enter> key
(g. 7a-d).
•When the message ‘Enter drill width’ is
displayed, enter the width via the keypad,
and conrm with <Enter>.
•Wait for about 5 seconds before switching
off with the <On/Off> button.
•When switching on again, the
manufacturer’s settings have been loaded.
•The display language is English, and the
ground wheel radar factor is 0.00778 m/
impulse. If the machine has a ground wheel,
this factor must be re-entered (4.1.2).