VIEW MEMORY ?
COMMAND 40
View Event Memory
Description
Your system stores events that occurred since the last
time memory was cleared. Use COMMAND 40 to view
Event Memory.
Event Memory allows you or a service technician to
review events after they are cleared from the command
center’s display. ALARM SILENCED may scroll to
remind you that events are stored in Event Memory.
Each time you turn the system on, the Event Memory is
erased and the ALARM SILENCED message is
cleared.
40
Using View Memory:
1. Ensure your command center shows idle disarmed text.
2. Press the COMMAND bar. The display shows
SYSTEM COMMAND.
3. Press the 4 key, followed by the 0 key.
Note: If you prefer, you may use the Command Menu in
place of steps 2 and 3 to initiate this function. Press the
MENU key to enter the Command Menu, then press
NEXT repeatedly until you reach the VIEW MEMORY
? prompt. Press ENT.
4. Your system displays event summary lines and point
text in this order: fire alarm summary line, point text
for each fire alarm event; alarm summary line, point
text for each alarm event; fire trouble summary line,
point text for each fire trouble event; trouble summary
line, and point text for each trouble event. Press NEXT
to scroll through the events. If there are no events to
view, NO EVENTS displays.
5. Return to idle text at any time by pressing ESC.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Radionics Security System 8112 and is the answer not in the manual?

Radionics Security System 8112 Specifications

General IconGeneral
BrandRadionics
ModelSecurity System 8112
CategorySecurity System
LanguageEnglish

Related product manuals