The No.1 way E1 works in balanced mode and is
matched with the impedance at the RX side.
The No.2 way E1 works in unbalanced mode and
is matched with the impedance at the RX side
The No.2 way E1 works in balanced mode and is
matched with the impedance at the RX side
The No.1 way E1 works in unbalanced mode and
the TX side is grounded.
The No.1 way E1 works in balanced mode.
The No.2 way E1 works in unbalanced mode and
the TX side is grounded.
The No.2 way E1 works in balanced mode.
Before delivery, all bits of SW1 are ON.
4.4.7 Cables
When the interface impedance is 120 Ω, use the CBL-E1-DB9M/2RJ45-
2.5m cable to connect the RC3000E to the RJ45 head.
When the interface impedance is 75 Ω, use the CBL-E1-DB9M/4BNCF-
2.5m cable to connect the RC3000E to the BNC female interface.
4.4.8 Technical specifications
Dimensions: 155 mm (Width) × 100.5 mm (Depth) × 25 mm (Height)
4.5 RC3000-SUB-10FXS/10FXO