8 Gas connection
Notes
DANGER
Gas connections must only be set up by locally
authorized gas technicians!
Set up the gas connection line in accordance
with the rated thermal load specified on the
type label.
i
NOTICE
Unit malfunction!
If line pressure deviates from connection flow
pressure, contact gas supply company.
Maintain dynamic flow pressure in range of:
- 6,5“ - 10” w. c. for natural gas
- 10” - 15” w. c. for LPG
Otherwise:
> do not start the unit,
> shut off the gas connection to the unit.
i
NOTICE
Non-functioning unit!
Gas components are designed for maximum
connection pressure of 26” w. c. Higher oper-
ating pressures are not permitted and can
damage components.