- 34 -
Remove left grid shelf and air baffle.
Guide hose into steam inlet opening as far as
the mark
Note
The allocation of marks to unit size is described
in the instructions for the descaler pump.
Warning:
Aggressive chemical fluid – risk of chemical burns.
It is essential that you use: protective clothing,
safety goggles, gloves, facemask and the unit
manufacturer‘s descaler pump.
Insert hanging rack and fix hose with wire hooks
Place canister of descaling fluid in the cooking
cabinet and run the hose into the canister
Descaling fluid reacts with lime and can
foam over.
Very slowly fill with descaling fluid using the
appliance manufacturer’s descaling pump.
Warning:
Aggressive chemical fluid – risk of chemical burns.
There may be residues of the descaling fluid in the
hoses. Rinse the descaling accessories thoroughly
with water.
Wear: protective clothing, safety goggles, gloves
and facemask.
Electric appliances
6 x 1/1 GN 10 x 1/1 GN 6 x 2/1 GN
3,5 litres 6 litres 6 litres
10 x 2/1 GN 20 x 1/1 GN 20 x 2/1 GN
8,5 litres 9 litres 11,5 litres
Gas appliances
6 x 1/1 GN 10 x 1/1 GN 6 x 2/1 GN
4 litres 7 litres 6,5 litres
10 x 2/1 GN 20 x 1/1 GN 20 x 2/1 GN
9 litres 8 litres 11 litres
Remove the descaling accessories (hand
pump and canister) from the cabinet.
Servicing - Steam generator descaling
7
8
10
11
9