EasyManua.ls Logo

Rational SelfCooking Center - Before you call customer service

Rational SelfCooking Center
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 71 -
Fault indications
Service 25 Indicated for 30 seconds during CleanJet
®
not functioning!
CleanJet
®
cleaning Turn water tap on full
• Check supply fi lter
• Remove containers from cooking cabinet
If you cannot identify the fault please notify
Customer Service.
If Service 25 appears when CleanJet
®
cleaning is running, please remove tablets
from cooking cabinet and rinse cabinet
thoroughly with hand shower (including
behind the air baffl e).
Unit can be used to cook for short periods.
Please notify Customer Service!
Service 26 Continuous indication If fault indication appears when CleanJet
®
cleaning is running, please initiate „CleanJet
®
Abort“.
If the fault indication still shows after „CleanJet
®
Abort“, please remove tablets from the cooking
cabinet and rinse cabinet thoroughly with hand
shower (including behind the air baffl e).
Please notify Customer Service!
Service 27 For 30 seconds after switching on CleanJet
®
system fault!
Isolate unit from power supply for 5 seconds
at point of power connection.
Service 28 For 30 seconds after switching on Please notify Customer Service!
Service 29 Continuous indication Please check air fi lter under the control panel
and clean or replace if necessary.
Check whether an external heat source is
affecting the unit.
Please notify Customer Service if the service
notice persists!
Service 30 For 30 seconds when switching on Moisture regulation not functioning! Unit can
be used for cooking to a limited extent. Please
notify Customer Service!
Service 31 For 30 seconds after switching on Core temperature probe defective! Unit can be
used for cooking without core temperature
probe. Please notify Customer Service!
Service 32 Continuous indication. Shut off gas gap!
Gas units only Please notify Customer Service!
Service 33 Continuous indication after 4 Resets Shut gas tap!
Gas units only Please notify Customer Service!
Service 34 Displayed continuously. Please notify Customer Service!