Delta-T
62° 11°
20 °
C
62° 11°
0:24
settings
Prog
h:m
m:s
- 54 -
Delta-T cooking
Delta T = difference between core temperature and
cooking cabinet temperature.
By gradually raising the temperature in the cabinet
until the cooking process ends and maintaining a
constant differential to the current core temperature,
the meat is cooked more slowly (can only be selected
in Combi-Steamer mode).
Select cooking mode Press the Function button Select Chef’s hat button
Press Delta T button Set Delta temperature Set required core temperature
Alternatively, you can set a time window for the Delta T cooking time.