Page #58 background imageLoading...
Page #58 background image
APPENDIX A
54 Hawkeye® 2 Installation Manual for AGCO RoGator C-Series (RG900, RG1100, RG1300)
3. Clean contacts with a small wire brush (P/N 321-0000-477).
FIGURE 2. Cleaning Contacts with a Wire Brush
4. Spray the contacts again with the deoxidizing agent to help rinse out debris.
5. Remove residue of the deoxidizing agent from the connection.
6. Dry out the connection with dry, compressed air such as Dust Off Electronics Duster (P/N 222-4001-007) or
equivalent air duster suitable for electronic components.
NOTE: If using compressed air from a large volume air compressor, be sure the lines are free of moisture.
FIGURE 3. Electronics Duster Used on NCV
CAUTION
Damage to the connector seal may occur if
residue is not removed from the connector.