EasyManua.ls Logo

Raven SCS 4600 - CAN Networking and CAN Data Menu; Detecting CAN Nodes

Raven SCS 4600
70 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
LIQUID AND GRANULAR
APPLICATIONS
CONSOLE CALIBRATION
1. CALCULATING "BOOM CAL" (LIQUID APPLICATIONS)
1) Broadcast Spraying
Calculate the width of each boom in inches [cm] by multiplying the number of tips times the spacing.
Write these boom widths down for future reference when programming the Console.
FIGURE 4
2) Band Spraying
Calculate the width of each boom in inches [cm] by multiplying the number of tips by the spacing.
Calculate the Adjusted Applied Rate by multiplying the Broadcast Rate by Band Width in inches [cm]
divided by Spacing in inches [cm].
EXAMPLE: Broadcast Rate = 20 GPA [200 lit/ha]
Spacing = 40 inches [100 cm]
Band Width = 14 inches [40 cm]
Adjusted Applied Rate= GPA x Band Width
Spacing
= 20 x 14 = 7 GPA
40
= [200] x [40] = [80 lit/ha]
[100]