APPENDIX 7
VERIFICATION OF SPREADER CONSTANT
To verify and refine the Spreader Constant, perform the following procedure (after completing INITIAL
CONSOLE PROGRAMMING):
1) Weigh loaded truck and note weight.
2) Enter the Product Density in lbs/cu.ft. [grams/liter] into key labelled .
3) Enter a "0" into the key labelled .
4) With the rate switch in the MAN position, unload a portion of the load by positioning the boom switch
to ON.
5) Determine the actual weight unloaded by re-weighing the truck.
6) Compare to the TOTAL VOLUME displayed by the Console.
7) Perform the following calculation to correct the Spreader Constant if desired:
Corrected Spreader Constant =
old Spreader Constant x TOTAL VOLUME
actual weight unloaded
EXAMPLE: old Spreader Constant = 228 [797]
TOTAL VOLUME amount = 2000 lbs [4400 kg]
actual weight unloaded = 1950 lbs [4290 kg]
English (US):
Corrected Spreader Constant (1 lb) = 228 x 2000 = 234
1950
Metric (SI):
Corrected Spreader Constant (1 kg) = [797] x [4400] = [817]
[4290]
This is the new Spreader Constant. Repeat this procedure until the weight of the metered material
equals the TOTAL VOLUME value.

Table of Contents

Other manuals for Raven SCS 4600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Raven SCS 4600 and is the answer not in the manual?

Raven SCS 4600 Specifications

General IconGeneral
BrandRaven
ModelSCS 4600
CategoryMusic Mixer
LanguageEnglish

Related product manuals