EasyManuals Logo

Raycus RFL-C2000S-HP User Manual

Raycus RFL-C2000S-HP
57 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #51 background imageLoading...
Page #51 background image
Wuhan Raycus Fiber Laser Technologies Co., Ltd
User Guide
RFL-C2000S-HP /RFL-C3000S-HP /RFL-C4000S-HP/RFL-C6000S-HP
51
Figure 29 Waveform written successfully
Click "Refresh program list" again, and the newly added waveform number will turn green,
indicating that the writing is successful. Click the program number, it will show that the read is
successful:
4.11.7 Command interpretation
Table 19 detailed explanation of waveform command word
Command code (1
byte)
Parameter 1 (2
bytes)
Parameter 2 (4 bytes)
Description
1
STOP
None
None
The end-of-program
command, which must
be the last entry for each
program
2
SPT
0-65000ms
0-65000(W)
It takes time for
parameter 1 to change
the power to parameter 2
3
SPR
0-65000W/ms
0-65000(W)
Change the power to
parameter 2 by the rate
of change of the power
of parameter 1

Questions and Answers: