Wuhan Raycus Fiber Laser Technologies Co., Ltd
User Guide
RFL-C2000S-HP /RFL-C3000S-HP /RFL-C4000S-HP/RFL-C6000S-HP
52
4
WAIT
1
Wait time
0-65000ms(int)
5
GOTO
0-99
line
0-10000
The number of
times to jump to
that row
The number of times the
loop jumps to the line
number
6
EXTPower
1
0-10V
4.12 Steps of close
Turn off the lasers in the following orders:
a) Turn off the laser;
b) Disconnect the 1/4 and 2/3 pins of the CTRL-INTERFACE;
c) Disconnect the pins 8/9 of the CTRL-INTERFACE;
d) Turn off the chiller;
e) Disconnect the air switch;
f) Close the head protection cap.