3.Sailyourvesseldirectlyintothewindandadjust
theanalogpointertozero,usingtheVMGand
Tackbuttons.
TheVMGbuttonwilldecreasethecurrentvalue
andtheT ackbuttonwillincreasethecurrent
value.Asyoudothis,thewindangleoffset
showstheamountofcorrectionyouhaveapplied.
4.ToexittheUserCalibrationMenuatanytime
pressandholdtheDisplayandTrue/App
buttonsatthesametimeforapproximately2
seconds.
Selectingtheunitofmeasureforwind
speedreadings
Duringnormaloperation:
1.PressandholdtheDisplayandTrue/App
buttonsatthesametimeforapproximately
2seconds,untiltheUserCalibrationpageis
displayed.
2.PresstheDisplaybuttonuntiltheWindSpeed
Unitspageisdisplayed(2pressesfromtheUser
Calibrationpage).
3.UsetheVMGorTackbuttonstoselectthe
requiredunitofmeasureforwindspeedreadings.
Theavailableunitsofmeasureforwindspeed
are:
•KTS(default)—Knots
•M/S—Meterspersecond
4.ToexittheUserCalibrationpagesatanytime
pressandholdtheDisplayandTrue/App
buttonsatthesametimeforapproximately2
seconds.
7.3Intermediatecalibration
Intermediatecalibrationallowsyouto:
•Checkinstrumentsoftwareversion
•*Checktheinstrumentstatus(eithermasteror
repeater)
Note:*Notavailableoni60CHWind.
Checkingthesoftwareversionand
instrumentstatus
Youcanchecktheinstrumentdisplay’ssoftware
versionandstatusbyfollowingthestepsbelow.
Note:Thei60CHWindinstrumentisarepeater
display.Youcannotcheckorchangethe
instrumentstatusofani60CHWinddisplay
Fromthesoftwareversionpage:
Duringnormaloperation:
1.PressandholdtheDisplayandTrue/App
buttonsatthesametimeforapproximately4
seconds,untiltheSoftwareVersionpageis
displayed.
2.PresstheDisplaybuttontoshowtheInstrument
Statuspage.
Theinstrumentstatusisdisplayed(r0=master
andr1=repeater).
Note:TheSoftwareVersionandInstrumentStatus
pagesaretemporarypagesandwilltime-out
automaticallyafter8secondsofinactivity.
Calibration39