7.4Dealercalibration
Thedealercalibrationproceduresinclude:
UsercalibrationmenuaccessOn(default)andOff.
DisplayResponseforwindanglereadings
Dictatestherateatwhichtheinstrumentdisplay
respondstochangesinwindangledata.
DisplayResponseforwindspeedreadings
Dictatestherateatwhichtheinstrumentdisplay
respondstochangesinwindspeeddata.
DisplayResponseforVMGreadingsDictates
therateatwhichtheinstrumentdisplayresponds
tochangesinVMGdata.
*BoatshowmodeOnandOff(default)(Boat
showmodeisonlyavailableondisplayssetas
repeaters).
Resettofactorydefaults.
Note:Notavailableonthei60CHwindinstrument.
SettingaccesstotheUserCalibration
Menu-i60
Duringnormaloperation:
1.PressandholdtheDisplayandTrue/App
buttonsatthesametimeforapproximately14
seconds,untiltheDealerCalibrationpageis
displayed.
2.PresstheVMGandTackbuttonsatthesame
timetodisplaytheUserCalibrationMenu
Accesspage.
CAL
3.UsetheVMGorTackbuttonstoswitchaccessto
theUserCalibrationMenuOnandOff.
UC1(default)UserCalibrationmenu
enabled
UC0UserCalibrationmenudisabled
Note:T oexittheDealerCalibrationpagesatany
time,pressandholdtheDisplayandTrue/App
buttonsatthesametimeforapproximately2
seconds.
SettingtheresponsedelayforWind
Anglereadings
Duringnormaloperation:
1.PressandholdtheDisplayandTrue/App
buttonsatthesametimeforapproximately14
seconds,untiltheDealerCalibrationpageis
displayed.
2.PresstheVMGandTackbuttonsatthesame
timetodisplaytheUserCalibrationMenu
Accesspage.
CAL
3.PresstheDisplaybuttonuntiltheWindAngle
Responsepageisdisplayed(1pressfromthe
UserCalibrationAccessMenupage).
4.UsetheVMGandTackbuttonstosetthe
requiredlevelforWindAngleResponse.
Thedefaultlevelis12.Thelevelsavailableare1
to15withlevel1beingtheslowestupdaterate
andlevel15thequickest.
Note:T oexittheDealerCalibrationpagesatany
time,pressandholdtheDisplayandTrue/App
buttonsatthesametimeforapproximately2
seconds.
SettingtheresponsedelayforWind
Speedreadings
Duringnormaloperation:
1.PressandholdtheDisplayandTrue/App
buttonsatthesametimeforapproximately14
seconds,untiltheDealerCalibrationpageis
displayed.
2.PresstheVMGandTackbuttonsatthesame
timetodisplaytheUserCalibrationMenu
Accesspage.
CAL
3.PresstheDisplaybuttonuntiltheWindSpeed
Responsepageisdisplayed(2pressesfromthe
UserCalibrationAccessMenupage).
4.UsetheVMGandTackbuttonstosetthe
requiredlevelforWindSpeedResponse.
Thedefaultlevelis12.Thelevelsavailableare1
to15withlevel1beingtheslowestupdaterate
andlevel15thequickest.
Note:T oexittheDealerCalibrationpagesatany
time,pressandholdtheDisplayandTrue/App
buttonsatthesametimeforapproximately2
seconds.
40

Table of Contents

Other manuals for Raymarine i60

Related product manuals