SettingtheresponsedelayforVMG
readings
Duringnormaloperation:
1.PressandholdtheDisplayandTrue/App
buttonsatthesametimeforapproximately14
seconds,untiltheDealerCalibrationpageis
displayed.
2.PresstheVMGandTackbuttonsatthesame
timetodisplaytheUserCalibrationMenu
Accesspage.
3.PresstheDisplaybuttonuntiltheVMG
Responsepageisdisplayed(3pressesfrom
UserCalibrationMenuAccesspage).
4.UsetheVMGorTackbuttonstosettherequired
levelforVMGresponse.
Thedefaultlevelis12.Thelevelsavailableare1
to15withlevel1beingtheslowestupdaterate
andlevel15thequickest.
Note:T oexittheDealerCalibrationpagesatany
time,pressandholdtheDisplayandTrue/App
buttonsatthesametimeforapproximately2
seconds.
SettingthewindspeedCalibration
Factor
Ifyoundthatyourwindspeedreadingsdeviatefrom
areferencedwindspeedsourcethenaCalibration
Factorcanbeappliedtoreducethedeviation.
Duringnormaloperation:
1.PressandholdtheDisplayandTrue/App
buttonsatthesametimeforapproximately14
seconds,untiltheDealerCalibrationpageis
displayed.
2.PresstheVMGandTackbuttonsatthesame
timetodisplaytheUserCalibrationMenu
Accesspage.
3.PresstheDisplaybuttonuntiltheCurrentWind
Speedpageisdisplayed(4pressesfromthe
UserCalibrationMenuAccesspage).
4.UsetheVMGandTackbuttonstoadjustthe
CalibrationFactortothedesiredvalue.
WhentheVMGandTACKbuttonsarenot
beingpressedthescreenwillrevertbackto
CurrentWindSpeedpagetoenableyoutosee
whatchangetheCalibrationFactorhasonthe
display’sWindSpeedreading.
Note:Toexitthedealercalibrationpagesatany
timepressandholdtheDisplayandTrue/App
buttonsatthesametimeforapproximately2
seconds.
EnablinganddisablingBoatShow
Mode-i60
Duringnormaloperation:
1.PressandholdtheDisplayandTrue/App
buttonsatthesametimeforapproximately14
seconds,untiltheDealerCalibrationpageis
displayed.
2.PresstheVMGandTackbuttonsatthesame
timetodisplaytheUserCalibrationMenu
Accesspage.
3.PresstheDisplaybuttonuntiltheBoatShow
Modepageisdisplayed(5pressesfromtheUser
CalibrationMenuAccesspage).
4.UsetheVMGorTackbuttonstoswitchtheBoat
ShowModeOnandOff(default).
SelectingOnwillputthedisplayintoboatshow
mode.
Note:Boatshowmodeisonlysuitablefor
demonstrationpurposesandshouldNOTbeused
whilstyourvesselisinuse.
Note:Toexitthedealercalibrationpagesatany
timepressandholdtheDisplayandTrue/App
buttonsatthesametimeforapproximately2
seconds.
Calibration
41