3.5Fusesandcircuitprotection
Powersupplycircuitprotection
Thepowersupplymustbeconnectedusinganappropriatelyrated
andfusedswitchorthermalbreaker.Thedrivetypedeterminesthe
ratingofthebreakerorfuserequired.
DriveunitSupplyvoltageFuse
Thermal
over-current
circuitbreaker
0.5lhydraulic
pump
12V15A10A
Type1(Rotary,
Linearor
Hydraulic)
12or24V25A20A
12V40A30A
Type2(Rotary,
Linearor
Hydraulic)
24V30A30A
Type3(
Hydrauliclinear)
12Vor24V40A30A
I/O
12V15A10A
CRpump
(Solenoid)
12or24V10A10A
Internalfuses
Thecoursecomputerusesstandardautomotivebladefuses.Spare
fusesarelocatedonundersideoftheremovablecover.
Rayma rine
GR OUND
P OWER
P OWER
P OWER
12 V
OF F
ON
24 V
FLUXGATE
RUDDER
CLUTC H
FAULT
S LEEP
FAULT
MOTOR
A B
D119 37-1
2
1 3
1.SeaTalk
ng
fuse.(Fusepowersupplyfromcoursecomputerto
SeaTalk
ng
backbone.
2.SeaTalkfuse.(Fusepowersupplyfromcoursecomputerto
connectedSeaT alkdevices).
3.Powerfuse.(Fusetotalpowerconsumedbysystem,including
thedriveunit.)
SeaTalk
ng
SeaTalkPower
SPX-10
2A2A15A
SPX-30
3A3A40A
SOX-SOL
3A3A15A
Cablesandconnections