AppendixATechnicalspecication
Nominalsupplyvoltage12or24Vdc
Operatingvoltagerange
10Vto32Vdc
Fuse/BreakersPowersupplyfuse:
15A(SPX-10,SPX-SOL)
40A(SPX-30)
SeaTalkPowerout2Aat12V(fuseprotectedat2A)
SPX-10
3Aat12V(fuseprotectedat3A)
AllexceptSPX-10
SeaTalk
ng
Powerout2Aat12V(fuseprotectedat2A)
SPX-10
3Aat12V(fuseprotectedat3A)
AllexceptSPX-10
Powerconsumption(standby)
300mA
SeaTalk
ng
LEN(LoadEquivalency
Number)
1
GyroInternalGyroPlusttedasstandard
Environmentalconditionsoperating
temperaturenon-operating
temperaturerelativehumidity
limitwaterprotection
Installationenvironment
Operatingtemperature:-10ºCto
+50ºC(14ºFto122ºF)
Storagetemperature:-20ºCto
+65ºC(-4ºFto149ºF)
Relativehumidity:max95%
Dripresistantwhenmounted
vertically
Dimensions
Width:285mm(11.2in)
Height:212mm(2.5in)
Depth:65mm(8.3in)
Weight
1.1kg(2.42lbs)SPX-10
2.2kg(4.85lbs)SPX-30
DataConnenctionsNMEA0183:I/O4800baud
SeaTalk
ng
SeaTalk
Otherconnections
Fluxgatecompass,Rudderposition
sensor,Sleepswitch,Power,drive
motor,driveclutch/SOLbypassvalve
NMEA0183fastheadingoutput(HDM)5Hz0.1°resolution
Technicalspecication
45