62 SmartPilot X-5 Wheel Installation & Setup Guide
Wheel Drive
Wheel Drive unit technical specification
Nominal supply voltage 12 V dc
Operating voltage range 10 V to 16 V dc
Motor Speed No Load: 6.5 - 11 RPM
Hard over speed:
2.5 turns: 15.75 Seconds Max
4 turns: 25.25 seconds max
Torque:
• Manual override torque:
• Continuous torque at helm:
• Peak torque at helm:
• Power off torque:
Max 4Nm
Max 6 Nm (14 V supply, 8.75 RPM)
18 Nm
Min 20Nm at clutch (to withstand back-driving)
Environmental conditions:
• operating temperature
• non-operating temperature
• water protection
-10°C to 55°C (14°F to 131°F)
-20°C to 70°C (-4°F to 158°F)
To IPX6 standard
Storage conditions when
packed:
temperature range
relative humidity limit
-20°C to 50°C (-4°F to 122°F)
75%
Inputs Drive power from compatible Course Computer.
Servicing Raymarine approved service at 1000 hrs intervals
EMC compliance: Europe 2004/108/EC (EMC)
Australia and New Zealand: C-Tick, Compliance Level 2
Helm tested to: EN29775 Section 7.2.2 Helm assembly tests.
BSEN28848 Helm impact test.
87074_2.book Page 62 Wednesday, November 21, 2007 3:55 PM