EasyManua.ls Logo

Raymarine ST70+ - Hard over Time

Raymarine ST70+
73 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 3: Commissioning Procedures 31
3. When the
PORT
result page is displayed, press
either
OK
if the rudder moved to port, or
CANCEL
if the rudder did not move to port.
4. If you press
OK
a second
Motor Check
caution
page is displayed.
5. If it is safe to proceed. press
OK
, then check
which way the autopilot drives the rudder.direc-
tion.
6. If you press
OK
a second
Motor Check
caution
page is displayed.
7. When the
STBD
result page is displayed, press
either
OK
if the rudder moved to starboard, or
CANCEL
if the rudder did not move to star-
board.
8. If you press
OK
a task complete page is dis-
played.
9. Press
OK
to end the autopilot dockside wizard.
Hard over time
Note: Not applicable to boats with a rudder reference transducer.
On boats without a rudder reference transducer, it is of critical importance to set the
hard over time, to ensure accurate autopilot operation. To do this:
At a convenient Pilot Controller:
1. Press
MENU
to display the
Main Menu
.
2. Scroll to
Autopilot calibration
then press
OK
to display the
Autopilot Autocalibra-
tion
menu.
3. Scroll to select the
Drive settings
option then press
OK
to display the
Drive settings
menu.
i
Press OK for YES
Motor Phasing Non-referenced
Did the rudder move to PORT?
Press CANCEL for NO.
D11613-1
Please press OK if it is safe to
engage the rudder drive in
the opposite direction.
Motor Check
Press CANCEL to stop
D11617-1
i
D11618-1
Press OK for YES
Motor Phasing Non-referenced
Did the rudder move to STBD?
Press CANCEL for NO.
i
Motor Check
Press CANCEL to stop
Task Complete - success
D11613-1
87099_1.book Page 31 Thursday, March 12, 2009 10:18 AM