TM018 Raypak 131 Type A Pool & Spa Heaters REV: A
D.O.I: 8/04/2009
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
36
Fault Finding Tests 7 9
Test 7
Test 8A
Using a multimeter on the AC voltage
scale, measure between terminal marked
„A and terminal marked „N on the line
terminal block.
The following result should be obtained:
240 Volts AC.
Using a multimeter on the AC voltage
scale, measure between terminal marked
„24VAC‟ and terminal marked „GND‟ on the
control board.
The following result should be obtained:
24 Volts AC.
Test 8B
Test 9
Using a multimeter on the AC voltage
scale, measure between terminal marked
„24VAC‟ and terminal marked „GND‟ on the
control board.
The following result should be obtained:
24 Volts AC.
Remove glass fuse from fuse holder. Using
a multimeter on the ohms scale, measure
between the ends of the glass fuse.
The following result should be obtained:
0 ohms (fuse ok).